TECHNICAL DATA - TABLEAU DES DONNÉES TECHNIQUES
CERT.
H
O
2
MAX
H
O
2
H
O
2
!
IMPORTANT: In order to have a correct function you must use an electrical generator in class G3 or more (frequency va-
riation ±1%, tension variation ±2%). The maximum power of electrical generator must be three time the nominal power of device
that you must connect.
MODEL
MODÈLE
B 360
BV 290E
B 360
MP5155
Oil-Burning
Industrial Heater
379000 Btu/h
1950 cfm
2.74 gal/h
K-1 Kerosene
No. 1 or No. 2 Fuel Oil
27.7 gal
~120 V (-15%÷10%)
60 Hz
11.4 A 1.4 kW
231 lb
2.00 GpH 80°H
DANFOSS
188 PSI
1300 kPa
13 bar
FUEL PUM ADJUSTMENT
RÉGLAGE DE LA POMPE À CARBURANT
NOZZLE
PISTOLET
DANFOSS 2.00 GpH 80°H
DANFOSS 1.50 GpH 80°S
BV 290E
276300 Btu/h
K-1 Kerosene
No. 1 or No. 2 Fuel Oil
~120 V (-15%÷10%)
11.4 A 1.4 kW
1.50 GpH 80°S
PRESSURE
PRESSION
188 PSI
1300 kPa
174 PSI
1200 kPa
MP5155
Oil-Burning
Industrial Heater
1950 cfm
2 gal/h
27.7 gal
60 Hz
271 lb
DANFOSS
174 PSI
1200 kPa
12 bar
13 bar
12 bar