MCS BV 110E Manuel D'utilisation Et De Maintenance page 40

Table des Matières

Publicité

en
it
2. Connect the heater to the power plug and try to turn it on
3. Verify that pump pressure is the same as indicated in the attached technical tables and, if this is not
de
the case, turn the specific adjustment screw to restore the correct value (see section 4 under the
item fuel system)
es
D. Dirty or damaged nozzle
fr
1. Remove the upper mantle
2. Remove the combustion head from the combustion chamber
3. Remove the nozzle from the combustion head
nl
4. If the nozzle is dirty, do not try to clean it by inserting wires into the fuel outlet. Place the nozzle in a
non-flammable solvent and use compressed air to remove any dirt from the nozzle. Replace the worn
pt
or damaged nozzle with a new one (See section 4 under the fuel system item)
da
fi
Observed problem: The electrodes make a spark but the motor does not run
no
Possible cause
sv
A. Seized fuel pump
B. Defective motor
pl
C. Motor in thermal protection
D. Defective relay
ru
Repair procedure
cs
A. Seized fuel pump
hu
1. Disconnect the heater from the power plug
2. Remove the upper mantle
sl
3. Rotate the fan and establish if the pump is free to rotate
4. If the fan rotates with difficulty or if it is blocked, loosen the three dowels keeping the pump fastened
tr
to the motor
5. Replace the pump if necessary
hr
B. Defective motor
lt
1. Disconnect the heater from the electrical power supply
2. Disconnect the control panel and remove the wires powering the motor
lv
3. Connect the ohmmeter lead wires to the blue and brown wires and verify that the motor resistance is
not null. If this were not the case, the motor is defective and must be replaced. Properly adjust the
et
ohmmeter scale
ro
C. Motor in thermal protection
1. Disconnect the heater from the electrical power
2. If the thermal protection has tripped in the motor, it should be very hot. If that is the case, let it cool
sk
down and then try to turn it on again
bg
D. Defective relay
1. Disconnect the heater from the electrical plug
uk
2. Take apart the electrical panel and check the condition of the relay. When it intervenes, it makes a
typical noise that may help establish if it is broken or not
bs
el
Observed problem: The motor starts but the heater does not ignite
zh
Possible cause, if a spark is not observed at the spark plug
A. Incorrect electrode positioning
B. Defective equipment
C. Broken electrode
19