Ignition transformer
The transformer returns a high voltage and amperage. Before carrying out maintenance
interventions on the transformer, always remember to detach the power supply plug.
Use the utmost care when testing the transformer since electrical shocks may occur.
ATTENTION!!!
The ignition transformer works at 120V - 60Hz. It works in
continuous operation during the entire ignition cycle of the
machine and it does not have internal spare parts; once it
becomes defective, it must be replaced in its entirety.
The transformer returns a high voltage and amperage. Before
carrying out maintenance interventions on the transformer,
always remember to detach the power supply plug. Use the
utmost care when testing the transformer since electrical
shocks may occur.