8.
insTaLLaTiOn
8.1.
safety instructions
Danger!
danger – high pressure in the equipment!
• Before loosening the lines and valves, turn off the pressure and
vent the lines.
Warning!
risk of injury from improper installation!
• Installation may be carried out by authorised technicians only
and with the appropriate tools!
risk of injury from unintentional activation of the system and
an uncontrolled restart!
• Secure system from unintentional activation.
• Following assembly, ensure a controlled restart.
Warning!
for control function i – danger if pilot pressure fails!
For control function I control and resetting occur pneumatically.
If the pressure fails, no defined position is reached.
• To ensure a controlled restart, first pressurize the device with
pilot pressure, then switch on the medium.
Type 2301
Installation
8.2.
Before installation
• The globe control valve can be installed in any installation position,
preferably with the actuator in upright position.
• Before connecting the valve, ensure the pipelines are flush.
• Make certain the flow direction is correct (Flow direction always
below seat).
8.2.1. preparatory work
→
Clean pipelines (Sealing material, swarf, etc.).
devices with welded body
Remove the control unit from the actuator (if present):
→
Clamp the valve body in a holding device.
→
Loosen the fastening screws (2x).
→
Remove the control unit upwards.
Fastening screw
(2x)
Fig. 7:
Disassembly the control unit
english
Control unit
Actuator
21