Installation; Fluid Installation; Safety Instructions; Electrical Installation - Burkert 6650 Manuel D'utilisation

Electrovanne flipper 2/2 ou 3/2
Masquer les pouces Voir aussi pour 6650:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

For OEM electronics (PWM) recommended circuit diagram:
Circuit diagram for 24 V design
R1
3k3 (24V)
D1
ZMM5.1V
1k2 (12V)
GND
GND
VDD
VDD
R3
R2
D5
100k
41k
1N4148
D3
1N4148
C3
D4
C2
1N4148
100nF
470pF
GND
GND
10
5

INSTALLATION

5.1 Safety instructions

DANGER!
Danger – high pressure in the equipment.
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
WARNING!
Risk of injury from improper installation.
▶ Installation may be carried out by authorised technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following installation, ensure a controlled restart.
The add-on dimension must not fall short of 4.5 mm!
Insert the sealing gasket into the valve.
Correctly allocate the fluid connection configuration 1, 2 and 3 to
the valve and the manifold.
Screw valve onto the manifold.
12
VDD
C1
D2
1uF
BYM05-200
GND
VDD
R4
8
4
TR1
330R
7
IRLL2705
3
6
5
2
TI1
1
TLC555
GND
GND
english
Flange screws
Recommended
torque:
0.35 Nm ± 0.1 Nm
Sealing gasket
Manifold
english
for resistance reduction:
Switch-on pulse 100 % nominal voltage for 5 ms, then holding voltage 35
% nominal voltage
U
100 %
35 %
0
Switch-on pulse
For OEM electronics (resistance reduction) recommended circuit
diagram:
Circuit diagram for 24 V design
Alternatively series or parallel connection of several resistors

5.2 Fluid Installation

DANGER!
Danger – high pressure in the equipment.
▶ Before loosening the lines and valves, turn off the pressure and
vent the lines.
Installation position:
any, actuator preferably upwards.
Procedure:
Before installation, clean any possible dirt off the pipelines and
flange connections.
Install a dirt trap to prevent malfunctions (Mesh size:
5 µm).
WARNING!
Danger through spillage of medium.
Leaking connections if seal seated incorrectly.
▶ Ensure that the supplied sealing gasket is seated correctly.
english
Dimensional drawing for manifold:
2-way normally closed:
max. ∅ 1.4
4.8
33
Check valve for leakage.

5.3 Electrical Installation

NOTE!
Without proper power reduction electronics, the valve type 6650
is not suitable for continuous operation! Please refer to the
chapter titled "4.5 Electrical data".
In the block structure all valves must be poled identically. The
mark (+) on the valve and the numerals 1 and 2 on the plug-in
connector are used as orientation. Example: On all units the
plug-in connector with numeral 2 points to the mark (+).
holding voltage
switch-off point
5 ms
t
Caution : Drop approx. 1.6 W
11
3-way universal function:
max. ∅ 1.4
4.8
33