7.2.
before installation
Installation position:
Installation can be in any position.
Preferably: Actuator upright.
→
Prior to installation check pipelines for dirt and, if required,
clean.
Dirt filter: To ensure that the solenoid valve functions reliably,
a dirt filter (≤ 500 µm) must be installed in front of the valve
inlet.
7.3.
installation
→
Hold the device with a suitable tool (open-end wrench)
on the housing and screw into the pipeline.
note!
Caution risk of breakage!
•
Do not use the coil as a lever arm.
→
Observe direction of flow:
The arrow on the housing indicates the direction of flow
(no function in opposite flow direction).
7.5.
changing valve function
Fig. 3:
Installing the pilot valve (changing valve function)
Danger!
Discharge of medium due to leaking device!
If the O-rings are forgotten or incorrectly inserted during
installation of the pilot valve, the device will be damaged
and medium will be discharged.
•
Before screwing in the pilot valve, correctly insert
O-rings into the depressions.
english
17
max. 2.0 Nm
Pilot valve
O-rings
Identification for the
flow direction
english
19
7.4.
manual emergency actuation
Caution!
Discharge of medium due to loss of the O-rings!
•
If the O-rings are lost, the valve will leak. Medium may
be discharged.
note!
Caution!
•
When the manual emergency actuation is locked, the
valve can no longer be actuated electrically.
Manual emergency
actuation
Press
2
Turn
Fig. 2:
Manual emergency actuation
english
18
Function NC
The pilot valve is installed in such a way that the manual
emergency actuation points in the direction opposite to the
direction of flow arrow.
Function NO
The pilot valve is installed in such a way that the manual
emergency actuation points in the same direction as the
identification for the flow direction.
Function NC
Flow direction
Fig. 4:
Valve functions (NC/NO)
english
20
Type 5282
1
Function NO