Electrical Data; Fluid Installation - Burkert 0293 Manuel D'utilisation

Electrovanne 2/2 voies
Masquer les pouces Voir aussi pour 0293:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.8. electrical data

Connections
Power supply
Voltage tolerance
Nominal operating mode
Note the voltage and current type as specified on
the rating plate.
english
12

7.2. fluid installation

Danger!
Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the
pressure and vent the lines.
Installation position:
Installation can be in any position.
Preferably: Actuator upright.
Procedure:
Before installation, clean any possible dirt off the
pipelines.
Warning!
Risk of short-circuit or escape of media through
leaking screw joints!
• Ensure seals are seated correctly!
• Carefully screw together coil and device socket or
valve and pipelines!
Observe direction of flow of the valve (Fig. 1):
1→ 2 (P → A).
english
14
DIN EN 175301-803 Form A
for device socket Type 2508
220 - 230 V / 50 Hz
220 V UC / 0 - 60 Hz
± 10 %
long-term operation,
ED 100 %
7.
insTallaTiOn
7.1. safety instructions
Danger!
Risk of injury from high pressure in the equipment!
• Before loosening the lines and valves, turn off the
pressure and vent the lines.
Risk of injury due to electrical shock!
• Before reaching into the system, switch off the power
supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety
regulations for electrical equipment!
Warning!
Risk of injury from improper installation!
• Installation may be carried out by authorized techni-
cians only and with the appropriate tools!
Risk of injury from unintentional activation of the
system and an uncontrolled restart!
• Secure system from unintentional activation.
• Following installation, ensure a controlled restart.
Fig. 1:
Housing with identification of flow direction
Seal the pipe connection with PTFE tape.
The PTFE tape must not get into the device.
note!
Caution risk of breakage!
• Do not use the coil as a lever arm.
Hold the device with a suitable tool (Open-end wrench)
on the housing and screw into the pipeline.
Type 0293
english
13
Identification for flow
direction
english
15

Publicité

Table des Matières
loading

Table des Matières