3.2.5. Temperature ranges in the eX area
medium (seat seal ptfe)
max. t
environment
≤ dn 25
T6 85 °C
-10 - +45 °C
T5 100 °C
-10 - +60 °C
T4 135 °C
-10 - +95 °C
Tab. 1:
Temperature ranges EX area
Temperature class T4
140
130
120
110
Temperature class T5
100
Temperature class T6
90
80
70
60
50
40
30
20
10
0
10
20
30
40
50
60
70
Medium temperature [°C]
Fig. 2:
Temperature ranges EX area
8
> dn 25
-10 - +55 °C
-10 - +70 °C
-10 - +105 °C
Valves ≤ DN 25
Valves > DN 25
80
90 100 110 120 130
english
Type 2301
General Information
4.
generaL infOrMaTiOn
4.1.
contact address
germany
Bürkert Fluid Control System
Sales Centre
Chr.-Bürkert-Str. 13-17
D-74653 Ingelfingen
Tel. + 49 (0) 7940 - 10 91 111
Fax + 49 (0) 7940 - 10 91 448
E-mail: info@de.buerkert.com
international
Contact addresses are found on the final pages of the printed oper-
ating manual.
You can also find information on the Internet under:
www.burkert.com
4.2.
Warranty
The warranty is only valid if the device is used as authorized in accor-
dance with the specified application conditions.
4.3.
information on the internet
The operating instructions and data sheets for Type 2301 can be found
on the Internet at:
www.burkert.com