20
PERIODIC SERVICE
5. Replace the element every year or every 6
cleanings.
(1) Air cleaner body
(2) Element
(3) Wing bolt

(4) Evacuator valve

A Make sure the wing bolt for the element is tight
enough. If it is loose, dust and dirt may be sucked in,
wearing down the cylinder liner and piston ring
earlier and thereby resulting in poor power output.
A Do not overservice the air cleaner element.
Overservicing may cause dirt to enter the engine
causing premature wear. Use the dust indicator as a
guide on when to service.
BEvacuator valve
Open the evacuator valve once a week under ordinary
conditions - or daily when used in a dusty place - to get
rid of large particles of dust and dirt.
BFor the air cleaner with a dust cup
(optional)
Remove and clean out the dust cup before it becomes
half full with dust; usually once a week, or even every
day if the working surroundings are dusty.
Install the air cleaner dust cup with "TOP" indicated on
the rear of the cup in the up position. (However, it may
be installed in either direction when the cover is placed
at the lower part.)
A If the dust cup is mounted incorrectly, dust or dirt
does not collect in the cup, and direct attachments of
the dust to the element will cause its lifetime to
shorten to a great extent.
(1) Air cleaner body
(2) Element
(3) Wing bolt
(4) Dust cup
(5) "TOP" mark
BDust indicator (optional)
If the red signal on the dust indicator attached to the air
cleaner is visible, the air cleaner has reached the
service level.
Clean the element immediately, and reset the signal
with the "RESET" button.
(1) "RESET" button
(2) Dust indicator
(3) Service level
(4) Signal