Télécharger Imprimer la page

PREVOST H Serie Manuel De L'opérateur page 210

Masquer les pouces Voir aussi pour H Serie:

Publicité

202
Annexe D –
PID/
SPN
FMI
SID
1188
5
SID
1188
14
SID
1188
9
SID
1188
16
SID
1188
7
SID
1188
11
SID
1188
15
SID
1188
8
SID
1188
31
SID
1188
19
SID
1213
4
SID
1213
3
SID
1213
5
SID
1323
31
SID
1323
14
SID
1324
31
SID
1325
31
SID
1326
31
SID
1327
31
SID
1328
31
SID
1329
31
SID
1330
31
SID
1351
4
SID
1351
3
SID
1351
5
SID
1636
4
PID
1636
3
PID
1636
2
PID
1636
21
PID
1636
2
PID
1636
2
PID
1636
20
PID
1636
21
PID
2629
4
PID
2629
3
PID
2629
20
PID
2629
21
PID
2629
2
PID
2630
4
SID
2630
3
SID
2630
2
SID
2630
20
SID
2630
21
SID
2631
4
SID
2631
3
SID
2659
1
SID
2659
0
SID
2791
4
PID
2791
3
PID
2791
5
PID
2791
7
SID
2791
14
SID
2791
9
SID
2791
16
SID
Codes de diagnostics du système DDEC VI
PID/SID
CODE
ID
CLIGNOTANTS
32
1325
32
1432
32
1432
32
1432
32
1432
32
1432
32
1432
32
1432
32
1432
32
1432
257
1333
257
1333
257
1333
155
1433
156
1434
155
1435
155
1441
155
1442
155
1443
155
1444
155
1445
155
1446
155
1615
155
1615
155
1615
105
1511
105
1511
105
1511
105
1511
105
1511
105
1511
105
1511
105
1511
404
1513
404
1513
404
1513
404
1513
404
1513
272
1514
272
1514
272
1514
272
1514
272
1514
273
1515
273
1515
277
1515
277
1515
146
1521
146
1521
146
1521
146
1521
146
1521
146
1521
146
1521
DESCRIPTION DU CODE
Waste Gate Circuit Failed Open
Smart Remote Actuator 1 (Wastegate), No Failsafe Mode,
Motor Off
Smart Remote Actuator 1 (Wastegate), Failsafe Mode, Motor
Off
Smart Remote Actuator 1 (Wastegate), Temperature Fault
Smart Remote Actuator 1 (Wastegate), Failsafe Mode, Motor
On
Smart Remote Actuator 1 (Wastegate), Restricted Operability
Smart Remote Actuator 1 (Wastegate), Temperature Warning
Smart Remote Actuator 1 (Wastegate), Internal Test Running
Smart Remote Actuator 1 (Wastegate), Unknown Error Code
Smart Actuator Indicates Turbocharger Wastegate Position
Error
MIL Lamp Circuit Failed Low
MIL Lamp Circuit Failed High
MIL Lamp Circuit Failed Open
Cylinder 1 Misfire detected
Misfire Detected
Cylinder 2 Misfire detected
Cylinder 3 Misfire detected
Cylinder 4 Misfire detected
Cylinder 5 Misfire detected
Cylinder 6 Misfire Detected
Cylinder 7 Misfire Detected
Cylinder 8 Misfire Detected
Switchable Air Compressor Circuit Failed Low
Switchable Air Compressor Circuit Failed High
Switchable Air Compressor Circuit Failed Open
Intake Manifold Temperature Circuit Failed Low
Intake Manifold Temperature Circuit Failed High
Intake Manifold Temperature Plausibility Error
Difference Intake Manifold Temperature and EGR Temp. Less
Than Threshold (Low Box)
Difference Intake Manifold and I Cooler Temperature Out Less
Than Threshold (Low Box)
Difference Intake Manifold and I Cooler Temperature Out Less
Than Threshold (High Box)
Intake Manifold Temperature Drift (Low Box)
Intake Manifold Temperature Drift (High Box)
Turbocharger Compressor Outlet Temperature Circuit Failed
Low
Turbocharger Compressor Outlet Temperature Circuit Failed
High
Turbocharger Out Temperature, Temperature Too High (Low
Box)
Turbocharger Out Temperature, Temperature Too Low (High
Box)
Turbocharger Compressor Outlet Temp. Sensor, General
Temp. Plausibility Error
Charge Air Cooler Outlet Temperature Circuit Failed Low
Charge Air Cooler Outlet Temperature Circuit Failed High
Charge Air Cooler Outlet Temperature Sensor Plausibility Error
Charge Air Outlet Temperature Drift (Low box)
Charge Air Outlet Temperature Drift (High box)
Charge Air Cooler Outlet Pressure Circuit Failed Low
Charge Air Cooler Outlet Pressure Circuit Failed High
EGR Flow Target Error Diagnostic - Low Flow
EGR Flow Target Error Diagnostic - High Flow
EGR Valve Circuit Failed Low
EGR Valve Circuit Failed High
EGR Valve Circuit Failed Open
EGR Valve Position Incorrect
Smart Remote Actuator 3 (EGR), No Failsafe Mode, Motor Off
Smart Remote Actuator 3 (EGR), Failsafe Mode, Motor Off
Smart Remote Actuator 3 (EGR), Temperature Fault

Publicité

loading

Ce manuel est également adapté pour:

Pa1560