Profibus configuration examples
General remarks
Terminals can be either bit-oriented (digital) or byte-oriented (analog/complex).
-
-
-
The process image first shows the byte-oriented terminals, with the bit-oriented
terminals behind. With terminals of the same type, their position is also signifi-
cant. Due to the different ways of installing the terminals, it is not possible to
show a generally applicable process image. Therefore, each installation set is de-
scribed in signal order, with E97/A97 at the beginning.
IMPORTANT! The correct process image can only be determined using the ter-
minals that are actually plugged in.
Configuration
Arrangement of signals when using the component number installation set
examples
(4,100,458)
Input
Power source
E113 - E120
E121 - E128
E129 - E136
E137 - E144
E145 - E152
E153 - E160
E161 - E168
E169 - E176
E177 - E184
E185 - E192
E193 - E200
E201 - E208
E209 - E216
E217 - E224
digital terminals: KL1114, KL2134, KL2612
analog terminals: KL4001
complex terminals: KL 6021
Remarks
Unused
Character 1
Character 2
Character 3
Character 4
Character 5
Character 6
Character 7
Unused
Character 8
Unused
Character 9
Character 10
Character 11
Range
Activity
-
32 - 254
-
32 - 254
-
32 - 254
-
32 - 254
-
32 - 254
-
32 - 254
-
32 - 254
-
-
-
32 - 254
-
-
-
32 - 254
-
32 - 254
-
32 - 254
-
79