The DPV1-MSAC-C1 connection was activated by the mas-
ter, but no DPV1-MSAC_C1 connection was defined
6
Multi-configurator mode is not permitted if the CfgData
check is switched off.
8
Synchronous mode may only be activated if at least one DP
output byte is configured
10
The optimised input cycle is only possible in synchronous
mode
11
The length of the DP buffer exceeds the size of the DP
RAM in the Profibus Asic
12
The fast FreeRun mode must not be activated at the same
time as synchronous mode
Error while checking the CfgData
Error code 2
A byte in the CfgData is incorrect. The error argument describes in which
CfgData byte the error was detected (offset of the incorrect byte + 1).
Error code 5
The length of the digital outputs (in bytes) calculated using CfgData is incor-
rect. The error argument contains the expected byte length.
Error code 6
The length of the digital inputs (in bytes) calculated using CfgData is incorrect.
The error argument contains the expected byte length.
Error code 7
Displays various errors when checking the CfgData. The error argument descri-
bes the error.
Error argument
Description
1
Length of CfgData received is incorrect
2
Syntax of CfgData received is incorrect
3
DP input data calculated from the CfgData is too long
4
DP output data calculated from the CfgData is too long
Error during slave run-up
Error code 8
The length of the DP buffer exceeds the size of the DP RAM in the Profibus
Asic. The error argument contains the difference (divided by 8). Deactivation of
DP communication.
Error code 9
Displays various errors arising during machine run-up. The error argument de-
scribes the error.
Error argument
Description
1
The DP input data is too long (too many modules inserted)
2
The DP output data is too long (too many modules inser-
ted)
3
The CfgData is too long (too many modules inserted)