FUSE INSPECTION
FUSE INSPECTION
1. Remove:
S Fuse 1
S Spare fuse 2
2. Inspect:
S Fuse
Inspection:
S Connect a pocket tester to the fuse and check
it for continuity.
NOTE:
Set the tester selector to "Ω
Pocket tester:
90890-03112, YU-03112
S If the tester indicates
It must be replaced.
3. Replace:
S Blown fuse
Replacement steps:
S Turn off the ignition and the circuit.
S Install a new fuse of proper amperage.
S Turn on the switches to verify operation of the
electrical device.
S If the fuse blows again immediately, check the
circuit in question.
NOTE:
Install new fuses of proper amperage.
Description
Amperage
Main
Spare
WARNING
Do not use fuses of higher amperage rating
than that which is recommended. Extensive
electrical system damage and fire could re-
sult from the substitution of a fuse of im-
proper amperage.
2-30
INSP
ADJ
1" position.
the fuse is blown.
Quantity
10A
1
10A
1