Running  continuously  the  pump  at  zero  flow  or  below  the 
 
recommended minimum flow will cause damage to the pump. 
 
Never  run  the  pump  out  of  its  operating  limits.  Operating  the 
 
pump  at  higher  flow  rates  may  overload  the  motor  and  cause 
cavitations. 
 
Operating the pump at lower flow rates may cause a reduction of 
 
ball  bearings/bearing  lifetime,  overheating  in  pump  sealing 
chamber, instability and cavitations/vibration. 
 
Never remove protecting covers or coupling guard when pump is 
 
ready  to  run.  Those  parts  can  only  be  removed  during 
maintenance operations. 
 
2.5 SAFETY INSTRUCTIONS FOR INSPECTION 
AND INSTALLATION WORK 
The operator must ensure that all inspection and installation work 
 
are  carried  out  by  authorized  and  qualified  personnel.  The 
operators must be sufficiently informed and must know the content of 
these instructions and of the incorporated materials instructions before 
any operation is carried out on pumps and accessories. 
Access to the product must only be carried out when pump is at a 
 
standstill.  It  is  mandatory  that  the  procedure  described  in  the 
installation  and  operating  instructions  for  shutting  down  the  pumpset 
are fully respected. 
 
All  protections  and  security  devices  must  be  reactivated  or 
 
switched on immediately after works are ended. 
 
2.6 MODIFICATION  OF  EQUIPMENT  AND 
USE OF SPARE PARTS 
Modifying  the  product  is  only  permitted  after  agreement  of  Salmson. 
Use  of  genuine  spare  parts  and  accessories  authorized  by  the 
manufacturer ensure safety and proper work of the pump. 
 
2.7 IMPROPER USE : 
The operating safety of the product is only guaranteed for conventional 
use  and  in  accordance  with  the  technical  offer  and  this  operating 
instructions.  The  limit  values  indicated  in  the  relevant  catalogue/data 
sheet must not be exceeded. 
 
2.8 PUMPSET DELIVERED WITHOUT MOTOR 
When  pumpset  is  delivered  without  any  motor  (a  CE  integration 
certificate  has  been  supplied  with  the  pump)  it  is  the  end‐user's 
responsibility  to  ensure  that  all  regulation  requirements  are  respected 
to get a CE marking. 
Certification  of  the  complete  pump  set  will  be  from  integrator 
 
responsibility.  He  will  ensure  that  aIl  specifications  listed  in  this 
instructions are fully respected. 
 
2.9 SECURITY 
INSTRUCTIONS 
APPLIED  ON  EQUIPMENTS  USED  IN 
POTENTIALLY EXPLOSIVE ATMOSPHERE 
This  chapter  contains  operating  instructions  that  have  to  be 
 
considered  when  using  the  pump  in  a  potentially  explosive 
atmosphere.  The  ATEX  additive  supplied  with  the  pump  will  be 
considered as well. 
This chapter indicates supplementary instructions to : 
The  following  instructions  for  the  pump  and  pump  units  shall  be 
followed  when  the  equipment  is  installed  in  a  potentially  explosive 
atmosphere.  Ex‐proof  protection  is  ensured  only  if  the  pump  unit  and 
supplied  accessories  are  installed  according  instruction  given  in  this 
instruction  and  operating  manual.  Both  electrical  and  non‐electrical 
equipment  must  meet  the  requirements  of  European  Directive  ATEX 
94/9/EC. 
 
2.9.1
An  example  of  ATEX  equipment  marking  is  shown  hereunder  for 
information.  Dedicated  ATEX  classification  is  engraved  on  pump 
nameplate and indicated in the ATEX additive : 
 
With : 
EQUIPMENT GROUP : 
II = Non‐mining 
 
CATEGORY : 
2 = high protection (zone 1) 
3 = normal protection (zone 2)  
 
GAS or DUST : 
G = Gas 
Those pumps are not « D » Dust certified. 
 
PUMP PROTECTION : 
c = safe by construction 
X = respect special instruction for equipment integration 
 
MOTOR ENCLOSURE : 
Exd = flameproof 
Exd(e) = flameproof frame and increased safety junction box 
 
GAS GROUP : 
IIA ‐ Propane 
IIB ‐ Ethylene 
IIC ‐ Hydrogen 
 
MAXIMUM  SURFACE  TEMPERATURE  (Temperature  class  to  ATEX 
94/9/EC) : 
T1 = 450°C 
T2 = 300°C 
T3 = 200°C 
T4 = 135°C 
T5 = 100°C 
T6 = 85°C 
T(x) = variable temperature or pump used in several areas. 
2.9.2
Atex zone in which the pump is installed. 
TO 
BE 
 
Pump temperature class is as stated on the nameplate. It is based on a 
maximum  ambient  temperature  of  40°C.  (ask  SALMSON  for  higher 
ambient temperatures). 
The  surface  temperature  taken  on  pump  surface  is  influenced  by  the 
temperature  of  the  liquid  that  is  handled.  The  maximum  permissible 
6
 
Avoid excessive surface temperature, 
Avoid build up of explosive mixture, 
Avoid sparks creation, 
Prevent leakages, 
Ensure proper maintenance to avoid hazard. 
SPECIFIC  MARKING  INSTRUCTIONS  FOR 
ATEX 
II‐2Gc(x)‐Exd‐IIBT4 
FLUID TEMPERATURE 
Ensure  that  the  equipment  temperature  class  is  suitable  for  the 
hazard  zone.  It  is  the  plant  operator's  responsibility  to  select  the 

Publicité