With : 
c=calorific capacity of fluid in J/Kg.K 
g=gravity in m/s² 
H=pump head in m 
T
=liquid temperature in °C 
f
T
=surface temperature in °C 
o
=hydraulic efficiency at duty point 
=differential temperature 
v
 
Maximum flow vs lifting height 
Hydraulic  curves  are  given  for  a  suction  height  of  1  meter.  If 
 
suction  lift  is  higher  than  1  meter  then  the  maximum  pump  flow 
will be limited as follows : 
‐ ¾ of max flow if suction height is 3 m under suction flange level. 
‐ ½ of max flow if suction height is 6 m under suction flange level. 
 
See sketch below : 
 
5.2.2.4
Maximum  allowable  speed  and  number  of  starts 
per hour 
 
Maximum speed : 
The  maximum  speeds  are  indicated  in  the  table  below.  Maximum 
allowable speed depends on critical speed of each impeller size and on 
bearing bracket maximum allowable speed. 
PUMP SIZE 
S40 ; S41 ; S42 
S50 ; S51 ; S80 ; S82 
S45 ; S46 ; S60 ; S61 
S45‐4 ; S63 ; S68 ; S69 ; S83 ; S88 ; S100 ; S108 
S65 ; S66 ; S85 ; S105 ; S150 
S91 ; S121 ; S161 ; S201 
S180 ; S230 
S170 ; S220 
 
Number of starts per hour : 
Wait for pump full stop before starting up the pump again to avoid 
 
damaging the motor and the pump. 
Starting  frequency  depends  on  motor  type.  Ask  manufacturer  if 
 
necessary. 
 
A maximum of 6 starts per hour is recommended. 
MAXIMUM SPEED 
RPM 
Bi‐bloc and 
Close‐
bearing bracket 
coupled 
variants 
pumps 
4000 
3600 
3000 
3600 
3000 
2400 
2000 
1600 
1200 
 
5.2.2.5
AUTHORIZED  SPEED  AND  NUMBER  OF  STARTS 
PER HOUR 
Operating limits for contiuous duty at 50Hz : 
S 40 
S 45 
S 50 
If flow much higher than Q
S 60 
If flow much higher than Q
S 63 
If flow much higher than Q
S 68 
If flow much higher than Q
S 80 
If flow much higher than Q
S 83 
If flow much higher than Q
S 88 
If flow much higher than Q
S100 
If flow much higher than Q
S108 
If flow much higher than Q
S 65 
S 85 
S105 
S121 
S150 
S161 
S180 
 
If flow much higher than Q
S201 
If flow much higher than Q
S230 
If flow much higher than Q
S170 
S220 
S300 
 
5.2.2.6
TYPE OF HANDLED FLUIDS 
The  pump  is  used  to  handle  clear  or  laden  liquids  with  a  maximum 
viscosity  of  500  cSt  (mm²/s).  For  viscosity  higher  than  50cSt,  the 
discharge  pressure,  the  flow  and  the  hydraulic  efficiency  must  be  re‐
calculated. 
The solids content in the liquid should be limited to 80g/l with no 
long fibers content. Dryness max = 8%. 
 
Free passage depends on pump size: 
S40  S41  S42 
S50  S51  S65  S66  S68  S69 
S100  S105  S121 
10
 
Continuous duty 
YES 
YES 
YES 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
YES 
YES 
YES 
YES 
YES 
YES 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
 or if abrasive content is high, 
BEP
choose bigger pump size. 
YES 
YES 
PUMP 
MAX GAP (mm) 
S45  S46 
14x19 
Ø20 
S60  S61 
Ø17 
S63 
Ø22 
Ø25 
S83 
Ø27 
S80  S82 
Ø32 
S88  S108 
Ø35 
S91 
Ø37 
S85  S180 
Ø40 
Ø45 

Publicité