Operating  the  pump  at  lower  flow  rates  may  cause  a 
reduction  of  ball  bearings/bearing  lifetime,  overheating  in 
pump sealing chamber, instability and cavitations/vibration. 
Never  remove  protecting  covers  or  coupling  guard  when 
pump  is  ready  to  run.  Those  parts  can  only  be  removed 
during maintenance operations. 
 
2.5 SAFETY 
INSTRUCTIONS 
INSPECTION  AND  INSTALLATION 
WORK 
The  operator  must  ensure  that  all  inspection  and 
installation work are carried out by authorized and qualified 
personnel. The operators must be sufficiently informed and must 
know  the  content  of  these  instructions  and  of  the  incorporated 
materials  instructions  before  any  operation  is  carried  out  on 
pumps and accessories. 
Access to the product must only be carried out when pump 
is  at  a  standstill.  It  is  mandatory  that  the  procedure 
described  in  the  installation  and  operating  instructions  for 
shutting down the pumpset are fully respected. 
 
All protections and security devices must be reactivated or 
switched on immediately after works are ended. 
 
2.6 MODIFICATION 
AND USE OF SPARE PARTS 
Modifying  the  product  is  only  permitted  after  agreement  of 
Salmson.  Use  of  genuine  spare  parts  and  accessories  authorized 
by the manufacturer ensure safety and proper work of the pump. 
 
2.7 IMPROPER USE : 
The  operating  safety  of  the  product  is  only  guaranteed  for 
conventional  use  and  in  accordance  with  the  technical  offer  and 
this  operating  instructions.  The  limit  values  indicated  in  the 
relevant catalogue/data sheet must not be exceeded. 
 
2.8 PUMPSET 
DELIVERED 
MOTOR 
When  pumpset  is  delivered  without  any  motor  (a  CE  integration 
certificate  has  been  supplied  with  the  pump)  it  is  the  end‐user's 
responsibility  to  ensure  that  all  regulation  requirements  are 
respected to get a CE marking. 
Certification  of  the  complete  pump  set  will  be  from 
integrator  responsibility.  He  will  ensure  that  aIl 
specifications listed in this instructions are fully respected. 
 
2.9 SECURITY  INSTRUCTIONS  TO  BE 
APPLIED  ON  EQUIPMENTS  USED  IN 
POTENTIALLY 
ATMOSPHERE 
This chapter contains operating instructions that have to be 
considered when using the pump in a potentially explosive 
atmosphere.  The  ATEX  additive  supplied  with  the  pump  will  be 
considered as well. 
This chapter indicates supplementary instructions to : 
Avoid excessive surface temperature, 
Avoid build up of explosive mixture, 
Avoid sparks creation, 
Prevent leakages, 
Ensure proper maintenance to avoid hazard. 
The following instructions for the pump and pump units shall be 
followed  when  the  equipment  is  installed  in  a  potentially 
explosive  atmosphere.  Ex‐proof  protection  is  ensured  only  if  the 
pump  unit  and  supplied  accessories  are  installed  according 
instruction  given  in  this  instruction  and  operating  manual.  Both 
electrical  and  non‐electrical  equipment  must  meet  the 
requirements of European Directive ATEX 94/9/EC. 
 
FOR 
OF 
EQUIPMENT 
WITHOUT 
EXPLOSIVE 
2.9.1
SPECIFIC  MARKING  INSTRUCTIONS  FOR 
ATEX 
An  example  of  ATEX  equipment  marking  is  shown  hereunder  for 
information.  Dedicated  ATEX  classification  is  engraved  on  pump 
nameplate and indicated in the ATEX additive : 
 
II‐2Gc(x)‐Exd‐IIBT4 
 
With : 
EQUIPMENT GROUP : 
II = Non‐mining 
 
CATEGORY : 
2 = high protection (zone 1) 
3 = normal protection (zone 2) 
 
GAS or DUST : 
G = Gas 
Those pumps are not « D » Dust certified. 
 
PUMP PROTECTION : 
c = safe by construction 
X = respect special instruction for equipment integration 
 
MOTOR ENCLOSURE : 
Exd = flameproof 
Exd(e) = flameproof frame and increased safety junction box 
 
GAS GROUP : 
IIA ‐ Propane 
IIB ‐ Ethylene 
IIC ‐ Hydrogen 
 
MAXIMUM  SURFACE  TEMPERATURE  (Temperature  class  to 
ATEX 94/9/EC) : 
T1 = 450°C 
T2 = 300°C 
T3 = 200°C 
T4 = 135°C 
T5 = 100°C 
T6 = 85°C 
T(x) = variable temperature or pump used in several areas. 
2.9.2
FLUID TEMPERATURE 
Ensure that the equipment temperature class is suitable for 
the  hazard  zone.  It  is  the  plant  operator's  responsibility  to 
select the Atex zone in which the pump is installed. 
 
Pump temperature class is as stated on the nameplate. It is based 
on  a  maximum  ambient  temperature  of  40°C.  (ask  SALMSON  for 
use in higher ambient temperatures). 
The surface temperature taken on pump surface is influenced by 
the temperature of the handled liquid. The maximum permissible 
temperature  depends  on  the  ATEX  temperature  class  and  must 
not exceed the values indicated in the ATEX additive attached to 
the pump. 
The shaft seal and bearings temperature rise due to the minimum 
permitted flow rate are taken into account. 
The maximum fluid temperatures indicated below are given 
accordingly : 
T1  400°C 
T2  275°C 
T3  180°C 
T4  115°C 
T5  80°C 
T6  need SALMSON approval 
 
If there is a risk to run the pump on a closed discharge valve 
it  is  requested  to  monitor  surface  temperature.  Motor 
overload trips should be correctly calibrated. Proceed with regular 
cleanings if pump is installed in dirty or dusty environment. 