Technical Data; Conditions Of Use; Conformity To Standards And Directives; General Technical Data - Burkert 8012 Manuel D'utilisation

Masquer les pouces Voir aussi pour 8012:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature
-15 to +60 °C
Air humidity
< 80%, non condensated
Protection rating
• IP67 (version with M12 fixed
• IP65 (version with cable gland)
6.2.
conformity to standards and
directives
The device conforms to the EC directives through the following
standards:
• EMC : EN 61000-6-2, EN 61000-6-3
• Safety: EN 61 010-1
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure (S012 fitting of DN06 to DN65 in PP, PVC, PVDF, brass
or stainless steel): the device can only be used in the following
cases (depending on the max. pressure, the DN of the pipe and
the fluid)
type of fluid
Fluid group 1, par. 1.3.a
14
connector), female connector wired,
plugged in and tightened
conditions
DN ≤ 25 only
English
Type 8012
Technicaldata
type of fluid
Fluid group 2 par. 1.3.a
Fluid group 1 par. 1.3.b
Fluid group 2 par. 1.3.b
6.3.

General technical data

6.3.1.

mechanical data

component
SE12 electronic housing
Cable gland, M12 fixed
connector
Cable, 1 m
Seal exposed to the fluid
Seal exposed to the ambient air
Paddle-wheel holder
Paddle-wheel
Paddle-wheel axis and
bearings
Body of the S012 fitting
Screws
conditions
DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
PNxDN ≤ 2000
DN ≤ 200
material
PPS
PA
PVC, T
= 80 °C
max
FKM (EDPM on request)
EDPM
PVDF
PVDF
ceramic
stainless steel (316L/DIN1.4404),
brass, PVC, PP, PVDF
Stainless steel A4

Publicité

Table des Matières
loading

Table des Matières