Technical Data - Burkert 8030 HT Manuel D'utilisation

Masquer les pouces Voir aussi pour 8030 HT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Available versions of electronic
module se30 HT
All the electronic modules have to be connected via a male
fixed connector and are fitted with a flow sensor with coil.
supply voltage
12-36 V DC
2 pulse outputs,
NPN and PNP
without
1 sinus output
Order codes of the sensor-fitting S030 HT can be found
within the data sheet of type 8030 HT: refer to the data
sheet to select the fitting appropriate to the process.
English
12
Acc. to pressure directive 97/23/CE, the fitting can only
be used in the following cases (depending on the max.
pressure, the DN of the pipe and the fluid):
type of fluid
conditions
Fluid group 1 § 1.3.a only DN ≤ 25
Fluid group 2 § 1.3.a DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
Fluid group 1 § 1.3.b PNxDN ≤ 2000
Fluid group 2 § 1.3.b DN ≤ 200
General data
Pipe diameter
DN6 to DN50. The appropriate dia-
meter is determined using the flow
rate / DN / fluid velocity graphs. See
Table 2
Pressure class
Depends on the fluid temperature:
refer to the operating instructions of
the fitting used.
Fitting
S030 HT: refer to the related operating
instructions
English
14
output
order code
449694
449693
6.

TecHnicAl DATA

conditions of use
Ambient temperature
• Version with pulse outputs:
(operating)
-15 to +80 °C
• Version with sinus output:
-15 to +100 °C
Air humidity
< 80%, non condensated
Protection rating
IP65 acc. to EN 60529, female
connector wired, plugged and
tightened
conformity to standards and
directives
The device conforms to the EC directives through the
following standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure: The sensor-fitting S030 HT complies with
article 3 of §3 from 97/23/CE pressure directive.
Fluid temperature
• -15 to +125 °C
The fluid temperature may be restricted
by the fluid pressure: refer to the ope-
rating instructions of the sensor-fitting
S030 HT.
Type and data of the
refer to the operating instructions of
fluid
the fitting used.
Flow rate measuring
0,5 to 10 m/s
range
≤ ±
Accuracy, with standard
(1 % of the full scale + 3 % of the
K factor
measured value)*
≤ ± 0,5 % of the full scale
Linearity
± 0,4 % of the measured value*
Repeatability
* Determined in the following reference conditions: medium =
water, water and ambient temperatures 20 °C, min. upstream and
downstream distances respected, appropriate pipe dimensions
English
13
13
English
15
15

Publicité

Table des Matières
loading

Table des Matières