Burkert 8012 Manuel D'utilisation page 22

Masquer les pouces Voir aussi pour 8012:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Type of fluid
transparent to infrared rays
(optical sensor)
Max. temperature
Fitting in stainless steel, brass, PVDF:
of the fluid
a) 100 °C if the ambient temperature ≤ +45 °C
b) 90 °C if the ambient temperature is
between 45 °C and 60 °C
Fitting in PP: 80 °C
Fitting in PVC: 60 °C
Min. fluid
Fitting in stainless steel, brass: -15 °C
temperature
Fitting in PP or PVC: +5 °C
Fitting in PVDF: -15 °C
Fluid pressure
depends on the fitting material; see the
pressure / temperature diagramme in chap.
7.1
Fluid viscosity
300 cSt max.
Rate of solid
1% max.
particles
Measurement
0.3 m/s to 10 m/s (depending on the fitting)
range
≤ ± (0.5% of the full scale (10 m/s) + 2.5%
Measurement
accuracy
of the measured value), with standard K
factor
≤ ±0.5 % of the full scale (10 m/s)
Linearity
Repeatability
0.4% of the measured value
Measuring
magnetic or optical sensor
element
22
English
Type 8012
Technicaldata
Max. error [%]
10
8
6
4
2
1
2 3 4 5 6 7 8
-2
-4
-6
-8
-10
Velocity of fluid [m/s]
Fig. 2 : Measurement accuracy. These values were determined in
the following reference conditions:
medium = water, water and ambient temperatures 20 °C,
min. upstream and downstream distances respected,
appropriate pipe dimensions
Typical Bürkert
curve
9
10
With standard K
factor (no cali-
bration on site)

Publicité

Table des Matières
loading

Table des Matières