Technicaldata
6.

TechnicAl DATA

6.1.

conditions of use

Ambient temperature
-10 to +60 °C (without pH or Redox
probe)
Air humidity
< 85 %, non condensated
Protection rating
IP65 and IP67 with connectors plugged
in and tightened and electronic module
cover fully screwed down
6.2.
conformity to standards and
directives
The device 8202 or 8222 conforms to the EC directives through the
following standards:
• EMC: EN 61000-6-2, EN 61000-6-3
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
• Pressure: complying with article 3 of §3 from 97/23/CE directive.
Acc. to the 97/23/CE pressure directive, the device can only be
used in the following cases (depending on max. pressure, pipe
diameter and fluid):
type of fluid
conditions
Fluid group 1, §1.3.a
only DN25
type of fluid
conditions
Fluid group 2, § 1.3.a DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
Fluid group 1, § 1.3.b DN ≤ 25
or DN > 25 and PNxDN ≤ 2000
Fluid group 2, § 1.3.b DN ≤ 125
The UL devices conform to the following standards: