Type 8026 - 8036 - SE36
Technical data
6
TEchnicAl DATA
6.1
conditions of use
Ambient temperature
-10 to +60 °C
Air humidity
< 85%, non condensing
Protection rating
IP67 and IP65 with connectors plugged
according EN 60529
in and tightened and transmitter cover
fully closed
6.2
conformity to standards and
directives
6.2.1 conformities common to the 8026 and
the SE36
• EMC: EN 61000-6-2, EN 61000-6-3
• Vibration: EN 60068-2-6
• Shock: EN 60068-2-27
For UL devices (
Canada:
• UL 61010-1
• CAN/CSA-C22.2 n° 61010-1
) in the United States of America and
6.2.2 conformity to the pressure equipment
directive
The devices 8026 and the fittings S030, S070 and S077 comply
with article 3§3 of the pressure equipment directive 97/23/CE.
According to this directive, the product can only be used in the fol-
lowing cases (depending on max. pressure, pipe diameter and fluid):
type of fluid
conditions
Fluid group 1, par.
• Flowmeter 8026 and fitting S030:
DN ≤ 25 only
1.3.a
• Fitting S070 or S077: Forbidden
Fluid group 2 par. 1.3.a DN ≤ 32
or DN > 32 and PNxDN ≤ 1000
Fluid group 1 par. 1.3.b • Flowmeter 8026: DN ≤ 25 or DN > 25
and PNxDN ≤ 2000
• Fittings S030, S070 and S077:
PNxDN ≤ 2000
Fluid group 2 par. 1.3.b • Flowmeter 8026: DN ≤ 400
• Fittings S030, S070 and S077: DN ≤
200
English
9