Compact measurements.
−
More hygienic.
−
Advantages
Pressure stability.
−
compared to
Adjustable starting pressure.
−
traditional
Self-starts in case of alarm.
−
systems
Limited number of starts.
−
Pump blockage in the absence of water.
−
4. INSTALLATION AND CONNECTION
4.1 Pump installation
The pumps may contain small quantities of residual water from testing. We advise flushing them briefly with clean water before their
final installation.
-
The electropump must be installed in a well ventilated place, protected from inclement
weather and with an environment temperature no higher than 40°C.
-
A solid anchoring of the pump to its support base helps absorb any vibrations created
by pump operation.
-
Always fit the pump on a base with the intake opening horizontal and the delivery
opening vertical.
-
The pump must be installed exclusively in horizontal position
- Do not allow the metal pipes to weigh down on the pump openings, transmitting excessive
strain, so as not to create deformations or breakages. Anchor the pipes separately if possible.
- The suction pipe must be as short as possible. For suction depths of more than 4 metres or
with long horizontal stretches, it is recommended to use a suction pipe with a diameter larger
than that of the suction opening of the electropump.
- To avoid the formation of air pockets in the suction pipe, ensure a slight positive tilt of the
same towards the electropump.
- To avoid transmitting vibrations to the system, after delivery it is recommended to use the
flexible pipe that is supplied inside the packing.
- If it is not possible to use the flexible pipe to make the connection, use only Teflon tape.
- For any maintenance jobs it is recommended:
to fit an interception valve along the pipe, close to the pump,
•
to use a straight length of pipe, after delivery, for lifting the cover of the Active system
•
in the event of inspection.
At suction from a well it is indispensable to install a foot valve complete with filter.
ENGLISH
Built-in non return valve and pressure gauge.
−
Possibility of remote alarm reset.
−
Protection against overpressure.
−
(the pump stops at over 10 bar)
Anticycling protection.
−
Helps prevent the formation of ice inside the pump. body
−
with forced cyclic running.
18
Foot valve