Serielle Schnittstelle; Befehle; Serial Interface; Interface Sérielle - Ismatec MCP-CPF Mode D'emploi

Classe de protection ip 65
Table des Matières

Publicité

Hinweis
Der Antrieb MCP-CPF Process hat beim
Einschalten eine Verzögerung von 3
Sekunden, bis die serielle Schnittstelle
zuverlässig anspricht.
Please note
When switching on the MCP-CPF
Process drive, the serial interface will
only respond after a delay of 3 seconds.
Remarque
Le moteur MCP-CPF Process a un retard de
3 secondes lors de la mise en route jusqu'à
ce que l'interface sérielle fonctionne de
manière fiable.
GND
TxD
Masse
Sendedaten
Ground
Transmitted Data
Masse
Données envoyées
RxD
Empfangsdaten
Received Data
Données reçues
Kommunikationsparameter
Communication parameters
Paramètres de communication
Standardeinstellung
Default setting
Réglage standard
9600 baud, 8 bit,
1 stopbit, no parity
Alternative
1200 baud, 8 bit,
1 stopbit, no parity
MCP-CPF PROCESS, 14-017, REV. C

Serielle Schnittstelle

RS232 IN (Eingang, weiblich)
Der Anschluss erfolgt über eine
9-polige D-Buchse.
Adressierung
Jeder Befehl beginnt mit der
Pumpenadresse (1 – 8). Sie ist
werkseitig auf 1 eingestellt und kann
mit @ verändert werden (siehe auch
Grundeinstellungen Seite 18).
Die Adresse wird permanent
gespeichert (d.h. auch nach
Ausschalten des Antriebs).
Die Adressierung ermöglicht die
Ansteuerung von bis zu 8 ISMATEC
Pumpen mit einer RS232-Schnittstelle.
Aufbau der Befehle
Nach der Adresse folgt ein Zeichen
als Befehl. Manche Befehle haben
zusätzlich einen Parameter, der aus 4
bzw. 5 Ziffern besteht.
Der Befehl wird mit einem carriage
return (ASCII 13) abgeschlossen. Die
meisten Befehle quittiert die Pumpe
mit einem Stern *. Ja/Nein-Abfragen
beantwortet sie mit + (ja) oder – (nein).
Mehrstellige Antworten beschließt die
Pumpe mit (cr) ASCII 13 und (lf) ASCII 10.
Fehlerhafte Zeichensequenzen quittiert
sie mit einem #.
Zahlenwerte gibt die Pumpe als drei-
bis fünfstellige Zahl zurück. Vier dieser
fünf Stellen sind Ziffern, eine Stelle ist
entweder ein Dezimalpunkt oder eine
führende Leerstelle.

Serial interface

RS232 IN (female)
A 9-pin D-socket is available on the
rear panel of the pump.
Setting the pump address
Each command string begins with the
pump address (1 – 8). It is factory-set
at 1 and can be changed with @
(also refer to the basic settings
described on Page 18).
The address will be stored permanently
(even after the pump has been
switched off).
The assignment of the address enables
-
the user to control up to 8 ISMATEC
®
drives via one RS232 interface.
Structure of the commands
The address is followed by a character.
Some commands have an additional
parameter which always consists of
4 or 5 figures.
The command string is completed by
a carriage return (ASCII 13). The pump
confirms most of the commands with
an asterix *. Yes/No inquiries are
answered by + (yes) or – (no).
Multi-digit replies are concluded by (cr)
ASCII 13 and (lf) ASCII 10.
Incorrect command strings are
answered by #.
Numerical values are confirmed as 3 to
5-digit figures. Four of the five digits are
numerals, one digit is either a decimal
point or a preceding blank space.
Interface sérielle
RS232 IN (entrée femelle)
Le raccordement se fait par le biais
d'une douille D à 9 pôles (femelle).
Adressage
Chaque commande commence avec
l'adresse de pompe 1 – 8. Elle est réglée
par défaut sur 1 et peut être modifiée
avec @ (voir réglage de base, Page 18).
L'adresse est enregistrée de manière
permanente (c'est-à-dire également
après la mise hors service du moteur).
L'adressage permet la commande de
plu-sieurs moteurs ISMATEC
d'une seule et même interface RS232.
®
Structure des commandes
Un signe suit l'adresse en tant que
commande. Certaines commandes
ont en outre un paramètre comportant
toujours 4, respectivement 5 chiffres.
La commande se termine par un retour
à la ligne (ASCII 13). La pompe quittance
la plupart des commandes avec une
étoile *. Elle répond aux questions oui/
non avec + (oui) ou - (non).
La pompe termine les réponses
multipositions avec (cr) ASCII 13 et (If)
ASCII 10.
Les séquences de signes erronées
sont quittancées avec un #.
La pompe renvoie les valeurs
chiffrées sous forme de nombre de
trois à cinq positions. Quatre de ces
cinq positions sont des chiffres, une
position étant soit un point décimal,
soit un blanc en première position.
par le biais
®
40 of 65

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ism 919

Table des Matières