9.5
Software version display
Fig. 9.7
Fig. 9.8
9.6
Initial startup / Delivery state
Fig. 9.9
9.6.1
Basic setting / Display at operating level
The following settings appear on the display in delivery state after the pump is
switched on (ON/OFF switch to "I"):
Fig. 9.10
In order to change the settings which are preconfigured in the factory, see the
NOTE
corresponding menu options in chapter
9.6.2
Basic setting / Configuration
The following factory settings are defined in the configuration:
Fig. 9.11
417102214_EDPL_V60.docx
The current software version of the pump appears in the
top right of the main menu display (1).
Lower-case letters after the software number (2) describe
internal changes to the software which have no impact on
how the device is operated.
When a dongle board is connected (see chapter
Upgrading the
software version of this board appears to the right of the
software version of the pump (3).
Upon delivery, the pump is protected against gear oil
leakage by means of a seal on the oil fill aperture.
Operating mode:
Metering frequency / rate in: Strokes/min (120 strokes / min)
Operating state:
EDPL V60
to
EDPL V60
Prior to startup:
Replace the sealing plug on the oil
ATTENTION
fill aperture with the supplied
bleeder plug.
Internal
OFF (Start: press START / STOP button)
10.4
"Configuration".
Configuration:
Standard:
Language:
German
Unit:
Litres
Max. output:
100%
Code:
(-) not active
Auto start:
(-) not active
Metering lock:
(-) not active
Level contact:
(
Alarm output:
(
) alarm = relay on
Pulse memory:
(-) not active
Oval gear meter:
(-) not active
Metering controller: (-) not active
Metering monitor:
(-) not active
Batch:
(-) not active
83
8
"
PLUS
"), the current
see chapter:
10.4.3
10.4.4
10.4.5
10.4.6
10.4.7
10.4.8
) empty = contact open
10.4.9
10.4.10
10.4.11
10.4.12
10.4.13
10.4.14
10.4.15
Rev. 1.12.11