10.4.7

Configuration / Auto start

This function determines whether the pump is set to 'OFF' when the mains connection is re-
established following a power cut or if the pump should immediately recommence functioning
in the configured operating mode.

10.4.7.1 Selection

10.4.8

Configuration / Metering lock

If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II between PINs
metering lock") regardless of which operating mode is set.
10.4.8.1 Selection
10.4.9

Configuration / Level contact

This function specifies whether an open or a closed contact at the level input (plug I, see
chapter
7.2.5.1
signal") is regarded as level OK.
10.4.9.1 Selection
417102214_EDPL_V60.docx
3
"Pin configuration for slot I (3-pin) - Input for level pre-warning and empty
Fig. 10.28
-
+
4
(see chapter
7.2.5.4
Fig. 10.29
-
94
Auto start is inactive.
The pump goes to 'OFF' when the
mains voltage is connected.
(Default setting)
Auto start is active.
When the mains voltage is connected,
the pump starts functioning in the
configured operating mode.
"Installation of activation via a
Metering lock query inactive.
(Default setting)
Metering lock query active.
Fig. 10.30
= Contact open:
Level not OK (empty)
Contact closed:
Level OK (full)
(Default setting)
= Contact closed:
Level not OK (empty)
Contact open:
Level OK (full)