10.4.15.3 Display view in the operating level
NOTE
10.5
Calibration
Open main menu as descripted at chapter
Acknowledge your choice with the Start/Stop key. If you push the and keys at once
(Function: „Menü Exit") you get back to operating mode.
10.5.1
Overview
The procedure and display during the calibration process differ depending on whether or not
an oval gear meter (OGM) is connected.
Fig. 10.49
10.5.2
Calibration / Pump
10.5.2.1 Preparation
Fig. 10.50
417102214_EDPL_V60.docx
Fig. 10.48
Pos.
Description
1
Operating mode
2
Quantity still to be metered
3
Quantity metered per batch
4
Number of strokes in order to meter the configured quantity
With an oval gear meter installed, the remaining oval gear meter pulses are displayed
instead of the quantity still to be metered. The resulting strokes are also represented by
the total number of OGM pulses for the configured quantity
Connect pump ready for operation on pressure side
Fill a suitable measuring cylinder and insert the
10.1
and go to
calibration
(see chapter
7
"Installing the device").
suction line.
The volume of the measuring cylinder should be
1/50 of the metering pump rate in litres/h.
During the calibration process, the position of the
suction tube may not be changed. The calibration
of the metering pump is only valid for current
configured stroke length setting. Following a
change in stroke length, the calibration has to be
performed again.
100
by using the key.
Pump calibration:
•
see chapter
10.5.2
Calibration of the pump and OGM:
•
see chapter
10.5.3
Rev. 1.12.11