Software Version Display; Delivery Scope; Main Settings Of The Operating Mode/ Display At Operating Display - Ecolab EMP KKS E60 Manuel D'utilisation

Pompe deseuse à membrane
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Startup
9.6

Software version display

Software version
display 1
The current software version (pos. 1) is displayed in the top right of the main menu
screen.
Lowercase letters after the software number (pos. 2) describe internal software
modifications that do not affect the operation of the device.
If a dongle box or a MicroFlow
displayed to the right of the pump version.
9.7

Delivery scope

9.7.1

Main settings of the operating mode/ Display at operating display

'Internal' operating mode is set as standard in the strokes per minute display option.
On delivery, the following basic factory settings appear on the display when the main
voltage is switch on.
NOTICE!
With each stroke of the pump, the indicator in the upper right of the display
rotates 1 turn.
417101442 Rev. 12-02.2019
Software version display 2
PLUS
has been connected, the unit version (pos. 3) is
Operating mode:
Metering frequency / -
quantity:
Operating state:
62
internal
strokes/min
122 strokes/min at 50 Hz,
146 strokes/min at 60 Hz
OFF (in V 4.1, „Standby" in V4.0)
to start the pump press START / STOP key!

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Emp kks e60+

Table des Matières