10.5.2.2 Calibration / Start
Fig. 10.51
Re. :
The pump is running for 60 s. (The seconds count down from 60 to 0).
The calibration can be interrupted by actuating the Menu/Exit function.
NOTE
The number of maximum strokes / minute are dependent under Metering mode (Main menu)
and metering capacity (Main menu / Configuration).
Re. :
After the running process, the quantity removed from the measuring cylinder (see
chapter
This quantity is then entered as the calibration value (in ml or l).
10.5.3
Calibration / Pump with an oval gear meter (OGM
If a dongle board and an oval gear meter are connected and the "oval gear meter" function
(see chapter 10.4.12) "Configuration / Oval gear meter
is activated, the oval gear meter pulse rate recorded is automatically displayed at the end of
the calibration process.
This is offset against the specified calibration value. A correlation thus occurs between the
oval gear meter pulses and the metered quantity.
10.5.3.1 Preparation
Fig. 10.52
417102214_EDPL_V60.docx
10.5.2.1
"Preparation") must be read off.
Connect pump ready for operation on pressure side
(see chapter
Fill a suitable measuring cylinder and insert the
suction line.
PLUS
)
PLUS
(V60
& OGM or OGM
7
"Installing the device ").
The volume of the measuring cylinder should be
1/50 of the metering pump rate in litres/h.
During the calibration process, the position of the
suction tube may not be changed. The calibration of
the metering pump is only valid for current
configured stroke length setting. Following a change
in stroke length, the calibration has to be performed
again.
101
PLUS
only)")
Rev. 1.12.11