Key functions

Key
Fig. 9.3
Menu/Exit
Fig. 9.4
Start/Stop
Fig. 9.5
Test function
9.5

Description of display symbols

Display
Intern
MUL
DIV
x..xx mA
Charge
xxx /min
xx %
x.xx l/h
n =
x
xx.x mA
f = xx.x %
OFF
E60+
E60++
Alarm
9.6

Software version display

417101441_EMP_III_E60.docx
Description
MENU/EXIT function entry and exiting of the menu levels (keep keys pressed down together)
() Modify set values upwards
() Modify set values downwards
Start the pump
Stop the pump
Confirmation key (ENTER) for set values
Test function (endurance test)
Description
Pump's operation mode: the top right indicator in the display
stroke.
Level report is active (flashing display = low level advance warning, display is permanently
visible = empty report), see
and empty report or
10.3.8
Metering lock active, see
Configuration / Metering lock
Fault report, see
12.2
Alarm messages
Operation mode internal, see
Operation mode pulse multiplication, see
Operation mode pulse division, see
Operation mode current x – xx mA, see
Operation mode batch see
Display strokes / min at Operation mode internal
Display % at Operation mode internal
Display l/h at Operation mode internal see
Display at operation mode pulse, see
Display at operation mode current, see
Display of the current metering frequency in %
Pump is in operating state OFF (must be switched on)
Dongle box is connected, see
Dongle box and OGM
PLUS
Configuration / Oval gear meter
Alarm operation mode, see
The current software version (Pos.1) is displayed in the top
right of the main menu screen (Fig. 9.6 & 9.7).
Lowercase letters after the software number (Pos.2)
describe internal software modifications that do not affect
the operation of the device.
Fig. 9.6
Software version display
If a
dongle box
unit version
version.
Fig. 9.7
Software version display, pump version
7.2.3.1
Installing the suction pipe with low-level ad advance warning
Configuration / Low-level contact
7.2.4.3
Installing the control via the metering lock or
10.2.2
Operation mode / internal
10.2.3
Operation mode / pulse
10.2.3
Operation mode / pulse
10.2.4
Operation mode / current
10.3.14
Configuration / Batch
10.2.2.2
Display / setting operation mode internal
10.2.3.2
Display / setting operation mode pulse
10.2.4.2
Display / operation mode current
8
"upgrading to Version E60
are connected, see
8.2.1.1
12.2
Alarm messages
or a
MicroFlow
PLUS
Pos.
is displayed to the right of the pump
(
3)
- 97 -
makes a full rotation with each
10.3.7
Plus
"
Installing the oval gear meter or
has been connected, the
10.3.11
Rev. 13-10.19