Custom Handle Design Guide - Monogram ZKFN Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Design Guide - Flush Inset Installation for
CLEARANCES
15"
Min. to
Wall
115°
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to 90° if
clearance to adjacent cabinets or walls is restricted.
When Installed into a corner:
Allow 15" (38.1 cm) for a full 115° door swing and pan
removal. Allow 4" (10.16 cm) min. clearance when door
swing is adjusted to a 90° opening for pan access, but
pan removal is restricted.
INSTALLATION
ZKBFN720NII Unification Kit
• If you are installing two units, side by side, the
installation space must be 75" (190.5 cm) wide.
Note: Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished
cutout to calculate rough-in width.
• The water and electrical locations for each product
must be located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
Note: When implementing a dual installation, the factory
installed standard case trim should be used on the
handle side of each unit and the flush case trim supplied
with Flush Inset Kit ZKFN should be used on the hinge
side of each unit.

CUSTOM HANDLE DESIGN GUIDE

Custom handles must be used for flush installation. For
custom handle installation, counterbore holes in rear of
decorative panels must ensure 1/2" (1.27 cm) material
thickness remains for handle support. NOTE: The
counterbore must not exceed 1" (2.54 cm) in diameter.
1/2"
1/4"
3/4"
All-Refrigerator and All-Freezer
4" Min. to Wall
90° Door Swing
38-3/4"
15"
115° Door
Min. to
Swing
Wall
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door
swing product, a 1" (2.54 cm) clearance between the
units is required. Order ZKBFN720NII Unification Kit for
an integrated appearance on 2 custom panel models
installed side-by-side.
75" Finished Width
4-5/16"
Electrical
5-1/2"
9"
26-3/16" Minimum
Cutout Depth
Cold Water
Supply
85"
Finished
Opening
3-1/2"
3-1/2"
7"
3-1/2"
3-1/2"
Minimum distance from handle
side edge to handle center should
be 3-1/2" (8.89 cm)as shown.
7/8"
0.85"
1/2"
42
1"
15"
115° Door
Min. to
Swing
Wall
Wall View
24-3/16"
5-1/2"
Electrical
9"
Area
Cold Water
Supply
3-1/2"
3-1/2"
7-1/2" 7-1/2"
7"
3-1/2"
3-1/2" 3-1/2"
3-1/2"
3-1/2"
31-1000454 Rev. 0