THE INSTALLATION SPACE

23-3/4"
36"
NOTE:
Handle and handle
standoff depth is
23-3/4"
2-1/2". (Actual handle
may vary slightly.)
Free-Standing – Use
canopy top
Choose the location:
• This product has been designed as a free-standing
unit; however, if desired, it may also be built-in.
• These products may be closed in on the top and
three sides as long as the front is unobstructed for air
circulation and proper access to the door.
• Do not operate these products where the temperature
will go below 45°F (7°C) or above 120°F (49°C).
• Unit must be installed on a structurally sound and
level surface strong enough to support a fully loaded
refrigerator, or approx. 250 lbs.
The cutout depth should be 24"
The cutout dimensions shown allow for a full door
swing and access to the pull-out racks when installed in
standard 24" deep cabinets.
9" Max.
34-1/2"-35"
23-3/4" Min.
• The Outdoor/Indoor Refrigerator can be used free-
standing.
• If installing between frameless cabinets, a 1/2" wide
filler strip or side panel may be required on the hinge
side. The filler strip will act as a spacer between the
case and adjacent cabinet door swing. The width of
the opening must include the filler panels.
NOTE: In a standard 24" opening, the door will
protrude 1-1/2" forward of the surrounding cabinets.
4

Design Guide

23-3/4"
23-3/4"
Built-In – Remove
canopy top (if needed)
Locate
Outlet
8-1/2"
10-1/2"
24"
9"
Max.
1-1/2"
1-1/2"
23-3/4"
26"
Including
Handle
23-3/4"
THE INSTALLATION SPACE (Cont.)
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
34-1/4"
grounded 3-prong electrical receptacle recessed into
to 34-3/4"
the back wall as shown. Electrical must be located
on rear wall as shown. THIS PRODUCT MUST
BE CONNECTED TO A POWER SOURCE WITH
GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
PROTECTION WHEN INSTALLED IN AN OUTDOOR
LOCATION. LOCAL CODES MAY REQUIRE A
SEPARATE CIRCUIT.
PRODUCT CLEARANCES AND
LOCATION REQUIREMENTS
The Outdoor/Indoor Refrigerator is factory set for
a 110° door swing.
When installed in a corner:
• Allow 5-1/4" min. clearance on the hinge side for
the 90° door swing and to allow racks to slide out.
• Allow 15" minimum clearance on the hinge side for
a full 110° door swing.
• Test the door swing. Carefully open and close the door.
Adjust if the door makes contact with cabinetry.
Swing
110˚
502Dia21
34-1/4"
to 34-3/4"
15" Minimum
90˚
to Wall
Door
Swing
110˚
Door
90˚
5-1/4" Minimum
21-5/8"
23-5/8"
to Wall
1" = 2.5 cm; 1' = 0.3 m