The Installation Space; Dimensions And Clearances; Custom Handle Design Guide - Monogram ZIC360NHLH Instructions D'installation

Réfrigérateur encastré à congélateur en bas 36 po avec guide de conception
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

THE INSTALLATION SPACE

Finished Width
4-5/16"
10"
26-3/16" Cutout
85"
Depth
Finished
Opening
Water Supply
3-1/2"
7"
3-1/2"
3-1/2"
Water And Electrical Locations
Electrical and water supply must be located as shown.
The Cutout Depth Must Be 26-3/16" (66.52 cm)
Wooden cleats are required for flush installation. See
Side Cleats on page 29.
Cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot
exceed the 26-3/16" (66.52 cm) installation depth
shown. The top case trim overlaps the bottom of the
soffit.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on rear wall as shown.
• Water line can enter the opening through the floor
or back wall. Route SmartConnect
copper tubing between the cold water line and the
water connection location. The tubing should be
long enough to extend to the front of the refrigerator.
Installation of an easily accessible shut-off valve in
the water line is required.

CUSTOM HANDLE DESIGN GUIDE

Custom handles must be used for flush installation. For
custom handle installation, counterbore holes in rear of
decorative panels must ensure 1/2" (1.27 cm) material
thickness remains for handle support.
NOTE: The counterbore must not exceed 1" in diameter.
1/2"
1/4"
3/4"
31-49142 Rev. 2
Design Guide - Flush Installation
39"
Wall View
6"
Electrical
Area
75-1/2" From
Floor to Bottom
of Electrical Area
3-1/2"
7"
3-1/2"
kit or 1/4" O.D.

DIMENSIONS AND CLEARANCES

35"
Case Width
*83-1/2"
at
Rear
Depth Including
Handles 26-7/8"
Product Clearances
These refrigerators are equipped with a 3-position door
stop. The factory set 115° door swing can be adjusted
to 90° if clearance to adjacent cabinets or walls is
restricted.
90° Door Swing
90°
*Min. Distance to Wall: 4"
For a 90º door swing, allow 4" (10.16 cm) min.
clearance to wall. If the 90º door stop position is used,
pan access is maintained, but pan removal is restricted
Minimum distance on Fresh Food
Door from handle side edge to
handle center should be 3-1/2"
(8.89 cm) as shown.
Minimum distance on Freezer Door
from top edge to handle center on
the freezer drawer
7/8"
should be 1-1/2"
(2.54 cm)as
0.85"
shown.
1/2"
23
25-3/8"
Case Depth
* Shipping height. The
refrigerator can be
adjusted to fit into a cutout
*84" From
that is 85" (215.9 cm) max.
Floor to
height. Use leveling legs
Top Frame
and wheels for a maximum
1" (2.54 cm) height
adjustment.
36" Frame to
Frame Width
As Shipped
115° Door Swing
20-5/8"
Behind
Frame
38-3/4"
115°
1-1/2"
15" Min.
to Wall
3-1/2"

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Zicp360nhrhZics360nharhZics360nhdrhZics360nhbrhZipp360nhss

Table des Matières