CEILING MOUNTING
F. Match the 2 fixing guides (23) to the screws (8) and fix then by means of the nuts (9) and
washers (10)
8
23
10
9
G. Calculate the proper length of the column (14),
according to the formula L=H-1900mm. Cut the
exceeding column (14) part on the side were NO
LATERAL BORES ARE PRESENT
H. Insert them column (14) in the flange (7) and mark
on the column (14) the position of the bores on the
flange (7). Pay attention the orientation of the column in
relation to the dental unit. Remove the column and
carry out two Ø8 bores at the marked points
I. Fit on the column (14) the ring(15) at about 300mm
height (it is only temporary position to allow the
assembling)
J. Insert the ceiling light support (16) on the column (14)
K. Fit the column (14) in the special bore of the
column fixing flange (7)
L. Lock the screw (13) and the two screws (18) with he-
xagonal spanners (installation accessory). Tighten sturdily
the screw (13) and make sure the screws (18) have passed
through the bores on the column (14)
7
13
16
15
14
18