Error messages
The sauna control unit is equipped with diagnostic software which monitors system
statuses when it switches on and during operation. As soon as the diagnostic
software identifi es an error, the sauna control unit switches the sauna heater off.
Errors are indicated by a recurring warning tone and by fl ashing on the function
selector 2 and the intensity selector 3. Furthermore, "Err" appears in the ad-
ditional display 1. The error number appears in the intensity display 4.
Switch the sauna control unit off using the ON/OFF switch 6 and rectify the
error before switching the sauna control unit on again.
The following table describes the possible errors and their causes. If necessary,
tell the error number to your customer service specialist.
Error
Description
01
Safety shut-off
02
Safety temperature
limiter
04F1
Heater sensor error
05
Foil sensor error
06F2
Bench sensor error
08
Foil sensor
excess temperature
WORLD OF WELLNESS
Cause/rectifi cation
An object has been placed on the sau-
na heater. Remove any objects before
starting up the sauna heater again.
The maximum temperature of 139 °C
has been exceeded above the heater.
Defective heater sensor, poor contact,
or short circuit.
Defective foil sensor, poor contact,
or short circuit.
Defective bench sensor, poor contact,
or short circuit.
The maximum foil temperature
of 100 °C was exceeded.
p. 45/48