● User program
The user program enables favourite sauna settings to be saved and accessed
again. There are 5 preset user programs available which can be modified
according to user requirements.
● Automatic heating period limiter
The sauna control unit shuts down automatically after the maximum heating
period for safety reasons. The maximum heating period can be set to 6 h,
12 h, 18 h or 24 h.
● Excess temperature fuse
The excess temperature fuse is installed in the housing for the heater sen-
sor. Should the sauna heater continue heating after reaching the preferred
temperature due to a defect, the excess temperature fuse switches the sauna
heater off at a temperature of approx. 139 °C.
3.4.

Sensor operating modes

The sauna control unit can be operated with one or two temperature sensors.
Single-sensor mode (F1)
Single-sensor mode must be activated in the technician menu (see 8.2. Settings
in the technician menu on page 26).
In single-sensor mode, the sauna control unit is operated with the heater sensor
with excess temperature fuse (F1) only.
In single-sensor mode, the sauna control unit only displays the set temperature
as standard. The actual temperature is not displayed. Should the sauna control
unit display the temperature above the heater (F1) as an actual temperature
in single-sensor mode, it must be activated when starting up for the first time
(see 8.2. Settings in the technician menu on page 26)