Connecting The Additional Output (Optional); Connecting The Power Booster (Optional); Connecting Heater Sensor F1; Installing Bench Sensor F2 (Optional) - Sentiotec Pro C2 Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Installation instructions, only for experts
5.4.

Connecting the additional output (optional)

The additional output can, for example, be used for an infrared lamp or infrared
heat plates.
1. Guide the connection cable for the additional device through the cable bush-
ing 7 into the connection area for 230 V/400 V f.
2. Connect the power supply cables to the terminal strip c in accordance
with the connection diagram. Observe the operating instructions and safety
instructions for the respective device.
5.5.

Connecting the power booster (optional)

1. Guide the cable for the power booster through the cable bushing a into
the connection area for 230 V/400 V g.
2. Connect the cable for the power booster to the terminal strip e in
accordance with the connection diagram. To do so, use terminal
"ST1" for the safety circuit, and terminal "ST2" for the control circuit.
Observe the operating instructions for the respective device.
5.6.

Connecting heater sensor F1

1. Guide the wires for the heater sensor through the cable bushing 5 into the
low-voltage connection area 1.
2. Connect the red wires for the heater sensor to the terminals labelled "STB"
in terminal strip 2.
3. Connect the white wires for the heater sensor to the terminals labelled "F1"
in terminal strip 2.
5.7.

Installing bench sensor F2 (optional)

1. Guide the wires for the bench sensor through the cable bushing 4 into the
low-voltage connection area 1.
2. Connect the wires for the bench sensor to the terminals labelled "F2" in
terminal strip 2.