19. How to access the programming mode
NOTE ONLY if the item "Customer Progr." is set on "YES"
and the item "Program. block" is set on "NO".
To access programming press the PRG
following message will appear on the display:
CUSTOMER PROG.
KEY MENU
Access to menus: press a selection key.
Access and modification of sub-menus: Use the "+"
and "-"
(31) keys to position the cursor (black line) on the
desired line, then press the PRG
KEY MENU
Type
repetition
Water dose
grinder
MM1 cof, dose
Use the "+"
(30) and "-"
message or number.
19.1 Key menu - Coffee selection
Press one of the coffee dispensing keys (32) (the relative led
will remain on). The following message will appear on the
display:
KEY MENU
Type
repetition
Water dose
grinder
MM1 cof, dose
The following coffee selection parameters can be modified:
- repetition (it represents the number of distributions of the
selected drink, from 001 to 099);
- water dose (volumetric dosage pulses, from 0 to 999, with
increments of 1);
(29) key; the
(30)
(29) key.
+ u
1 coffee
001
110
MM1
u
064
(31) keys also to modify the
+ u
1 coffee
001
110
MM1
u
064
Note: During the Data Modification phase, the cursor turns
into " " or a slide bar with minimum and maximum settings
appears:
MM1 cof. dose
-5
-
The icons below appear in alternating order in the lower part
of the display:
Exiting the programming menu
- Press the
key to confirm changes;
- Press the RES
(24) key to leave settings unchanged and
exit the menu
If the "Customer Progr." is set to "NO", the following message
will appear on the display:
CUSTOMER PROG.
NOT ENABLED!
- grinder (chosen between grinder MM1 or MM2);
- coffee dose... (coffee dose grinde ...impulses, 0 ÷ 200 with
increments of 1);
- water start (determines if the water must be added (before)
or (after) the coffee dispensing);
- Additional water (volumetric dosage pulses, from 0 to 999,
with increments of 1).
The components - * - are applied only in some produit
configurations
The dose setting for both grinders has a field range of + 5 of
the value set in the technical programming menu.
Example
technical programming
coffee dose MM1 045
coffee dose MM2 020
80
064
064
+5
+
customer programming
coffee dose MM1 040÷050
coffee dose MM2 015÷025