Compressed Air Connections
Emptying the water / oil filter
34
TegraPol-21/ -25/ -31/ -35
TegraForce-3/ -5
Instruction Manual
The quality of the air in the compressed air system used with this
machine must meet the standards stated in ISO 8573-1. To connect
the TegraForce:
Mount the quick coupling on the pressure hose and secure it with
the hose clamp supplied.
Connect the air hose to the quick coupling and fit the other end
into the compressed air inlet on TegraForce-5.
The air pressure must be between 5 bar (72 psi) and 10 bar (145 psi) and
have a quality specified in ISO 8573-1.
TegraForce is fitted with a water / oil filter that removes excessive
amounts of these substances from the compressed air supply. As a
result of this, it is necessary to empty the filter periodically:
Remove the preparation disc from the work area. Failure to do
this may result in the preparation disc being contaminated by
water and oil particles landing on it.
Locate the release outlet valve on the bottom of the filter glass.
Hold a container under the filter to retain any water released and
press the release valve.
Replace the preparation disc.
IMPORTANT
Release Outlet Valve