Conditions d'utilisation pour la certification UL du PSD1-S

Catégorie
certifié
PSD1-S:
Risk of Electric Shock, wait at least 3 minutes avec PSD1-S et 10 minutes avec
PSD1-M before removing cover
Vous trouverez dans ce chapitre
• Certification UL ......................................................................................................................... 25
• Installations- & Environmental Characteristics PSD1-S ............................................................. 25
• Tightening torque of the wiring terminals .................................................................................. 26
• Auxiliary connection - electrical ratings .................................................................................... 27
• Data of integrated dynamic brake unit....................................................................................... 27
• In- / Output Ratings .................................................................................................................. 27
2.10.5.1

Certification UL

Spécification
Numéro fichier E : E142140
L'homologation UL est uniquement valable si la plaque d'identité de l'appareil contient le
symbole "UL" .
UL61800-5-1 1ière édition, publiée 8 juin 2012
C22.2 No.274-13, 1ière édition, publiée mars 2013
2.10.5.2
Installations- & Environmental Characteristics
PSD1-S
• Use in Pollution degree 2 Environment.
• Maximum Surrounding Air Temperature 40 °C.
• The devices must be appropriately protected (e.g. by a switching cabinet). - Open
type equipment.
• Use 60/75°C wires only
Use Copper Conductors Only
Do only use the Parker cables available under Accessories (voir page 95) or
assemble the cables according to the specified regulations.
• Control voltage supply (24 VDC) only permissible with "class 2" power supply.
• Grounding Terminals - the screw terminals are suitable for Field Wiring
Connection only when the wire is provided with Eyelet Tube Terminal.
• Overvoltage category III.
• Short circuit ratings SCCR = 5000 Arms
• The drive modules are equipped with a current limit. Values for maximum device
current and maximum motor current can be set via PSD ServoManager (Chapter
resp. Menu Limit values & Motor Characteristics).
• Integral motor overload protection is not available.
• The drive does not incorporate internal overload protection for the motor load and
this overload protection shall be provided in the end use applications.
• Motor over temperature sensing is not provided by the drive
193-011006N8 2019-11