The field wiring terminals should be tightened with the torques mentioned below.
Only the supplied mating connectors must be used.
PSD1-M
UL
X45 Motor
CE
Tightening torque
UL
X46 motor brake
CE
Tightening torque
PSD1M_1800
UL
X43 Motor
CE
Tightening torque
UL
X44 motor brake
CE
Tightening torque
Mains module
UL
X40: Ballast resistor
CE
Tightening torque
UL
X41: Mains connector
PSD1-M_P010
CE
Tightening torque
UL
X41: Mains connector
PSD1-M_P020
CE
Tightening torque
UL
X9: 24 VDC
CE
Steuerspannung
Tightening torque
UL
DC Bus
CE
Tightening torque
max 0.5mm
ferrule with plastic sleeve
*
2
193-011006N8 2019-11
193-011006N8 PSD1 Manuel d'installation
2 A ... 15 A
up to AWG10
up to 4 mm
2
0.8 Nm
7 Lb.in
up to AWG14
up to 1.5 mm
2
0.22 ... 0.25 Nm
1.95 ... 2.21 Lb.in
2 A ... 30 A
up to AWG20-8
up to 6 mm
2
1.1 ... 1.7 Nm
11 ... 15 Lb.in
up to AWG30-14
up to 1.5 mm
*
2
0.22 ... 0.25 Nm
1.95 ... 2.21 Lb.in
up to AWG10
up to 6 mm
2
0.46 ... 0.57 Nm (M3)
4 ... 5 Lb.in
up to AWG10
up to 6 mm
2
1,1 ... 1.7 Nm
11 ... 15 Lb.in
up to AWG6
up to 16 mm
2
1.7 Nm
15 Lb.in
up to AWG10
up to 6 mm
2
1.1 ... 1.7 Nm
11 ... 15 Lb.in
-
-
0.8 Nm
7 Lb.in
25.11.19 14:26
23 (126)