ELIMINATING FAULTS

10.1

ERROR MESSAGES IN THE DISPLAY

In the event of malfunctions during operation, the following error messages can appear in the display.
ERROR MESSAGES
POSSIBLE CAUSE
IN THE DISPLAY
ERR00
- Protective guard is missing or not in
correct position
- Temperature monitor in engine of
spiral pump (see Err02)
- Emergency off switch is activated
- System fault
ERR01
- High temperature of electronic
board (inverter)
ERR02
- Higher temperature of spiral pump
motor
- The motor has been overloaded for
too long.
ERR03
- The spiral pump motor is overloaded
(motor is blocked)
ERR04
- The spiral pump motor is revolving,
however it is overloaded
ERR05
- The compressor switches on and off
too frequently even through the air
tap to the spray lance is turned off
- Hole in air hose
- Leak at connections
ERR06
- Current supply voltage is higher
than 265 volt
ERR07
- Loss of voltage against ground or
system fault
ERR08
- Supply voltage is too low (below 170
volts)
46
ELIMINATION
- Check to see if the guard is positioned correctly
- Allow time to cool down before restarting
- Allow time to cool down before restarting
- Please contact Wagner Service
- Allow time to cool down before restarting
- Allow time to cool down before restarting
- Correct the mixture that is being used
- Add water to the mixture
- Add binding agent to the mixture
- Use sand with a suitable grain size distribution
- Remove blockage.
- Use sand with a suitable grain size distribution
- Add water to the mixture
- Add binding agent to the mixture
- Reduce the motor speed of the spiral pump
- When the machine is running, make sure that the supply volta-
ge is between 200 and 230 volt, that the supply cable is dimen-
sioned correctly and that no other devices (cranes, lifting units,
sawing machines, concrete mixers, etc.) are connected to the
same supply line.
- Replace spray lance
- Replace air hose
- Check connections
- Have the current quality at the output of the supply source
checked by a specialist.
- Please contact Wagner Service
- Check to see if water is penetrating the system
-
When the machine is running, make sure that the supply volta-
ge is between 200 and 230 volt, that the supply cable is dimen-
sioned correctly and that no other devices (cranes, lifting units,
sawing machines, concrete mixers, etc.) are connected to the
same supply line.