PlastMax
MALFUNCTION
Machine and/or compressor
does not stop
Machine stops after being put
into operation
The flow of the material is inter-
rupted (air bubbles)
The flow of the material is inter-
rupted
Material in lance is not consis-
tent - too hard or too liquid
The water in the mixing cham-
ber increases during operation
Water in the mixing chamber
increases when machine is at
standstill
POSSIBLE CAUSE
- Air hose defect (hose cut through? Is
air emerging from the connections?
- Compressor is not producing en-
ough pressure air
- Air tap to lance is defect (blocked in
open position)
- Pressure switch is defect
- Suction filter is blocked
- The filter on the pressure reducer is
blocked
- Water hose too long and/or too thin
- Water supply is not sufficient
- Mixer is not suitable for this product
- Mixing chamber is blocked with ma-
terial
- Material hose is blocked
- Blockage in spray lance
- Badly pre-mixed material
- The rotor-stator component is worn
- Mixer not suitable or worn
- The rotor-stator component is worn
- Magnet valve defect
ELIMINATION
- Check air hose, particularly the connection
screw points, and replace if necessary
- Check air filter (see chapter 8)
- Replace spray lance
- Please contact Wagner Service
- Check the following listed items: Clean filter,
check whether water throughput at water hose
is sufficient (min. 10-12 l/min for lime/cement
mortar, min 15-20 l/min for gypsum plaster). Re-
place the hose if necessary or draw water from
an additional tank
- Clean mixer and if necessary replace with one
that is suitable for the product
- Clean and dry the mixing chamber and continue
with work
- Remove blockage
- Check points listed alongside
- Replace rotor stator
- Check
GB