START-UP

The protective guard must always be moun-
ted properly and correctly. Removing the
protective guard causes any moving machi-
ne parts to stop.
To put the machine back into operation, the
protective guard has to be reinserted and
the main switch set to 0.
Only suitable dry material or premixed ma-
terial may be put into the container.
5.1

DRY MATERIAL

To avoid blockages, the mortar hose should
be rinsed. Attention! Water is not sufficient
as a sliding means. Danger of clogging!
Use cellulose paste (e.g. Metylan wallpaper
paste, art no. 2312136)
Set the selector switch for the operating mode (fig. 11, 19) to
pneumatic (for pneumatic lance) or automatic (for automatic
lance).
Fill cellulose glue into the mortar hose, connect to the material
outlet and secure with a clamping lever (4).
Disconnect the water hose (17) and the blind plugs (18) from
the connections.
Remove any remaining materials by moving the cleaning tool
back and forth (12). Afterwards, take the cleaning tool out of
the opening.
Depending on the material, the water hose
(17) should be fitted to a different connection:
materials that mix easily = lower connection
materials that do not mix easily = upper con-
nection
If necessary, remove the cover (18) and connect the water
house (17).
Press the water supply button (9) and keep it held until water
exits from the opening of the cleaning tool.
Re-insert the cleaning tool and close correctly.
Fill the container with the material from the sacks. (Fig. 13).
Set the water flow displayed on the flow meter (fig. 11, 14) with
the water volume regulator (13).
- for materials based on cement –> 300 l/h
- for materials based on gypsum –> 500 l/h
Turn the main switch (fig. 11, 1) on the switch panel to 1 in order
to switch on the compressor.
Activate the two buttons (fig. 11, 3) until the operating modes
2 or 3 are shown on the display (4).
Turn the start switch (fig. 11, 5) to operating position (to the
right).
Hold spray lance over an empty bucket.
Close the air flow regulator (fig. 12, 15).