Error Tables; Error Message - salmson LRE Instructions De Montage Et De Mise En Service

Circulateurs collectifs. ed.6-05/05
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
ENGLISH

11.6 Error tables

Problem
Pump does not run or stops
Pump runs at reduced
capacity
Noisy pump operation
11.6.1

Error message

Code
Error
No.
E01
Hydraulic overload
E04
Mains undervoltage
E05
Mains overvoltage
E06
Mains undervoltage
E10
Pump blocked
E20
Coil overheated
E21
Motor overload
E23
Short circuit/contact
fault
E25
Contact error
Coil interrupted
E26
Coil temperature sensor Motor faulty
interrupted
E30
Excess temperature –
module
E31
Excess temperature –
power section
E36
Module faulty
Possible cause
Loose cable connection
Faulty fuses
Shut-off valve on discharge
side restricted
Air in suction pipe
Inadequate admission pressure Increase admission pressure, observe minimum pressure at inlet,
Damage to motor bearings
Cause
Delivery rate too high
Mains overloaded
Mains voltage too high
Missing phase
e.g. sedimentation
Motor overloaded
Water temperature too
high
Motor ventilation
restricted
Sediment in the pump
Operating point outside Check / correct operating point
performance data
Motor or module faulty
Module not properly
connected
Motor faulty
Air intake to module
heat sink is blocked
Ambient temperature
too high
Electronic components
faulty
Remedy
Tighten all connecting screws
Check fuses, replace faulty fuses
Slowly open shut-off valve
Remove leakages in the flanges and vent
check and if necessary clean valve and filter on inlet side
Have pump checked and if necessary repaired by SALMSON
Customer Service or specialist firm
Remedy
Reduce delivery rate
Check electronic installation
Check electronic installation
Check electronic installation
Unblocking routine starts automatically
If blockage is not removed after 10 s,
pump shuts down.Call customer service.
Allow motor to cool down,
check settings
Reduce water temperature
Free air intake
Call customer service
Call customer service
Call customer service
Call customer service
Call customer service
Free air intake
Improve ventilation in room
Call customer service
49
Error type
Error matrix
Error matrix
HV
AC
F
F
C
A
C
A
C
A
A
A
B
A
B
A
B
A
A
A
B
A
B
A
B
A
A
A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Jre

Table des Matières