T
D
ECHNICAL
ATA

Pneumatic data

Port connections
Pressure range
Air flow, control valve
Response times
Control range

Electrical data

Protection class
Operating voltage
without communication
with communication
Max. electrical power loss
Connections
Control heads
without communication:
Control heads
with communication:
ASI:
DeviceNet:
Solenoid valves
Nominal power
Operating mode
Proximity switches
Operating voltage
Output signal
Micro-switch
10 - 1066
Compressed air/Exhaust air
Service ports tube hose connection
6/4 mm or 1/4 inch, plug-in
2.5 to 7 bar
110 l/min Type 6510, 40 l/min Type 6106
Flow: Q
- value air (l/min)
Nn
Measurement at +20 °C, 6 bar pressure at the valve inlet and 1 bar
pressure difference
Type 6510 / Type 6106
Opening 15 / 23 ms
Measurement at valve outlet at 6 bar and +20 °C
Opening:
pressure rise 0 to 90 %
Closing:
pressure fall 100 to 10 %
min. stroke 2mm
max. stroke 73 mm
IP 67
24 V DC ±10 %
24/110/230 V UC ±10 %
in accordance with the ASI and DeviceNet specification
5 W for 3 x Type 6510 or 1 x Type 6106
Multipol (8-pole round plug DIN 45326) for 24 V DC
(8-pole screw terminals) for 24 V DC
2 x 6-pole screw terminals for 24/110/230 V UC
Cut-clamp connector and cable fitting
M12 plug and cable fitting
M12 flange plug, 4-pole
5-pole M12 plug connection
1 W Type 6510 / 3 W Type 6106
continuous (ED 100 %)
8 to 30 V DC
max. 100 mA, short-circuit proof
potential-free, max. 1 A switched current
G 1/4
Closing 10 / 21 ms