STRUCTURE AND FUNCTION

The flipper valve Type 6114 is a 3/2-way solenoid valve
which can be operated electrically (mono or bistable).

TECHNICAL DATA

Operating Conditions

WARNING!
Risk of injury due to malfunction.
Malfunction if used outside!
• Do not use Type 6114 outdoors and avoid heat sources
which may cause the permitted temperature range to
be exceeded.
Ambient temperature:
Medium temperature:
Media:
Compressed air lubricated,
non-lubricated or dry;
neutral liquids and gases (5 µm filtration);
technical vacuum
Protection class: IP65
Protection class: 3 as per VDE 0580
english
8
Type label
Example: Precontrol for bistable tapware (pulse version)
Order no.
english
10
5 to +55 °C
5 to +55 °C FFKM
0 to +55 °C EPDM
Voltage (±10 %)
Type
Pressure range
Nominal width
Sealing material
Operating principle
Output
Mechanical Data
Dimensions
See data sheet
Housing material
PPS, fibre-glass reinforced
Sealing material
EPDM / FFKM
WARNING!
Risk of injury from discharge of medium through
damaged seals.
Unsuitable medium may damage the sealing material
(brittleness, destruction, swelling).
• Use only media suitable for the sealing material.
• If you have any queries, please consult our staff.
Pneumatic Data
Operating principles D
Precontrol for
3/2-way valve, direct-acting,
tapware
disconnected
output 2 pressurised
Fluid connections
1
P
Pressure connection
2
B
Working connection
3
R
Exhaust air connection
Pressure range
see type label
R seat
Type 6114
english
9
B
P R
P seat
B
english
11

Publicité

Table des Matières