R
EPAIRS
Changing the valve on versions for 24 / 110 / 230 V UC without
communication
For the verion for 24/110/230 V UC without communication only valve model 6106 is exchanged while
paying attention to operating voltage. The valve connection plate remains in the control head.
Proceed as follows:
Remove the cover.
Unscrew the screws on the appliance socket.
Pull the appliance socket from the valve.
Note the mounting position of the tag connectors and the manual
override.
Loosen the 2 fixing screws on the valve body.
Remove the coil bobbin.
Loosen the 2 fixing screws on the valve body.
Remove the valve body complete with its O-rings.
Fit the new valve body together with its O-rings on the correct side
(manual override to the left)
Retighten the screws alternately and evenly
(tightening torque 0.5 Nm).
Fit the new coil bobbin on the correct side
(long tag connector to the left).
Alternately and evenly tighten the coil screws
(tightening torque 0.15 Nm).
Mount the appliance socket on the valve.
Secure the socket with a screw
(tightening torque 1 Nm).
Refit the cover.
34 - 1066
Valve
Type 6106