Technical data

B
A
Normally open by spring action.
P
A
I
Actuating function via reciprocal pressurization.
P
6.2.2 flow direction below the seat
Depending on the version, the valve is closed against the medium
flow with spring force (control function A, CFA) or with pilot pressure
(control function B or I, CFB or CFI).
As the medium pressure is under the control cone, this pressure con-
tributes to the opening of the valve.
Warning!
medium may be discharged if minimum pilot pressure is too
low or medium pressure too high!
If the minimum pilot pressure is too low for CFB and CFI or the
permitted medium pressure is exceeded, leaks may occur.
▶ Observe minimum pilot pressure.
▶ Do not exceed medium pressure (see chapter "Pressure ranges").
CFA
Fig. 1:
Flow direction below the seat
(Rest open/closed, closing against medium)
Type 2301
CFB / CFI
7
Technical DaTa
7.1
conformity
In accordance with the EC Declaration of conformity, Type 2301 ist
compliant with the EC Directives.
7.2
standards
The applied standards, which verify conformity with the EC Directives,
can be found on the EC-Type Examination Certificate and / or the EC
Declaration of Conformity.
According to Pressure Equipment Directive the following operating
conditions must be observed:
Maximum pressure for compressible fluids
Line connection
of Group 1 (hazardous gases and vapors
orifice
according to Art. 3 No. 1.3 Letter a first
DN65
DN80
DN100
english
dash)
15 bar
12.5 bar
10 bar
7