6.5.
Type label (example)
Figure 3:
Example of type label
6.6.
pneumatic data
Control medium
Dust content
Water content
Oil content
Temperature range
Pressure range
Air output of pilot valve
Connections
6.7.
electrical data
6.7.1.
electrical data without bus control 24 V dc
Connections
Pilot valve
Supply voltage
Power input
Output
Display
14
Supply voltage / control
Type
8691 AS-i 62SI
single act
Pmax 7bar
Tamb 0°C - +55°C
Ser.-Nr. 001000
00179024
Identification number
neutral gases, air; Quality classes in accordance with DIN ISO 8573-1
Class 5
max. particle size 40 µm, max. particle density 10 mg/m
Class 3
max. pressure dew point
-20 °C or min. 10 °C below the lowest operating temperature
Class 5
max. 25 mg/m
-10 – +50 °C
3 – 7 bar
250I
/min (for ventilation and exhaust)
N
(Q
value according to definition for pressure drop from 7 to 6 bar absolute)
Nn
Plug-in hose connector Ø 6 mm / 1/4"
Socket connection G1/8
Cable gland M16 x 1.5, wrench size 22 (clamping area 5 – 10 mm)
with screw-type terminals for cable cross-sections 0.14 – 1.5 mm²
Circular plug-in connector (M12 x 1, 8-pole)
24 V DC ± 10 % residual ripple 10 %
max. 1W
max. 100 mA per output
max. 20 mA per illustrated illuminated display (LED)
english
Control function - pilot valve
Nominal pressure
Pilot 3,0
Max. ambient temperature
ce
W14UN
Serial number - CE mark
Bar code
3
Type 8691
Technical data
3