Function indicator

LED 1 illuminates in green
LED 1 flashes in green
LED 1 flashes briefly in green – Only in the event of opera-
LED 2 flashes in red
LED 2 illuminates in red

Red LED illuminates

The device is indicating a fault. Switch device off, wait for a
short time and switch on again. If red LED continues to illumi-
nate, please contact Truma Service.

Maintenance

There is a fluff filter (n) and a particle filter (p) on the front of
the device for cleaning the room air.
p
n
Fig. 4
The fluff filter (n) must be cleaned at regular intervals
(at least 2 x per annum) and changed if required (part no.
40090-64600).
We recommend replacing the particle filter (p) every year at
the beginning of the season (part no. 40090-58100).
The cold air ducts must be removed before replacing the fil-
ters. Pull the fluff filter (n) a little way forward at the recesses
at the top edge and remove from above. Then remove particle
filter (p) from the front.
Fig. 5
When installing the particle filter (p) the printed arrows
must point towards the device – they indicate the circu-
lated air flow direction. Never operate the device without
filters. Operating the device without filters can cause evapo-
rator coil soiling, which can have a detrimental effect on the
performance of the device!
18
– Cooling
– The circulated air fan runs,
and the compressor switches
itself on after no more than
3 minutes.
tion with power inverter: Wait
for engine to start or function
change via remote control
– Data transfer in progress or
power supply being connected
– Fault
The condensation drain is under the floor of the vehicle. In
order to allow the condensation to drain away freely, check
whether the drain is free of dirt, leaves and the like at regular
intervals. Failure to do this may allow condensation to
penetrate the vehicle!

Troubleshooting

Is the motor home / caravan 230 V power supply lead prop-
erly connected, and are the fuses and circuit breakers OK?
Fault
Cause / Remedy
Device not cooling
– Thawing process in progress /
– The temperature set on the
Device providing insuf-
– Filters soiled / change filters.
ficient cooling or no
cooling at all
– External air routes soiled,
Moisture at cold air
– High air humidity / close win-
ducts
Remote control not
– Check batteries in remote
working
Device not reacting
– Check whether there are ob-
to remote control
commands
– Is the remote control tuned to
If these actions fail to remedy the fault, please contact Truma
Service.

IR remote control battery change

Only use micro-batteries that will not leak, type LR 3, AM4,
AAA, MN 2400 (1.5 V).
The battery compartment is on the rear of the remote control.
When inserting new batteries, make sure the positive / nega-
tive terminals are connected correctly!
Fig. 6
Empty, used batteries can leak and damage the remote
control! Remove the batteries if the remote control is
not being used for a long period of time.
The tuning between the remote control and the air con-
ditioning system is retained if the batteries are removed.
No warranty is given for damage caused by leaking
batteries.
wait until thawing process is
complete.
remote control has been
reached / set temperature on
remote control to less than
room temperature.
blocked / clear air routes.
dows and doors and select high
fan level.
control / replace batteries if
necessary.
structions between the remote
control and the IR receiver / re-
move obstructions if necessary
the IR receiver? / tune remote
control to IR receiver